Helium Leak Testing is done to trace or detect leaks in metals. The molecule of helium is very small that can pass through the smallest of leaks. Since this is inert, non-flammable, non-condensable and non-toxic gas. Although hydrogen has the smallest molecule but it is not inert and can react during testing. In conducting leak detecting tests, the Helium gas is circulated through the area to be tested. Helium Leak Testing is also known as Mass Spectrometer Leak Detector (MSLD) which is a test conducted for locating and detecting the size of leaks in a system. Under this broader category, we also provide other tests, such as Condenser Tube Helium Leak Detection, Heat Exchanger Helium Leak Testing, Fugitive Emission Testing and Helium Leak Detection Service.

Helium Leak Detection Service

  • Accuracy
  • Up to 1x10^-9 mbar l/s
  • Display
  • Digital screen
  • Gas Pressure
  • Up to 10 bar
  • Humidity
  • Up to 80% RH (non-condensing)
  • Net Weight
  • Approx. 45 kg
  • Number of Specimens
  • Single or Multiple
  • Operating Mode
  • Automatic / Manual
  • Operating Temperature
  • 5C to 45C
  • Operating Voltage
  • 230V AC
  • Pedestal Size
  • Adjustable as per specimen
  • Port Size
  • Standard / Customizable
  • Power Supply
  • AC 230 V, 50 Hz
  • Response Time
  • < 1 second
  • Sensor
  • High sensitivity helium sensor
  • Shell Material
  • Stainless Steel
  • Specimen Size
  • As per requirement
  • Temperature
  • Ambient
  • Test Material
  • Alloy/Steel/Custom material parts
  • Test Medium
  • Helium Gas
  • Test Range
  • 10^-9 to 10^-3 mbar l/s
  • Type
  • Other, Helium Leak Detection Service
  • Use
  • Leak detection in vacuum and pressurized components

ASNT Level II Helium Leak

Price 16000 INR/ Number

MOQ : 1 Number

  • Accuracy
  • 0.1 %
  • Color
  • White
  • Material
  • Mild Steel
  • Operate Method
  • Semi Automatic
  • Type
  • Electronic
  • Usage
  • Industrial
Inspection & Testing Engineers provides NDT Level I & Level II certifications as per ASNT SNT TC 1A in seven NDT methods like Ultrasonic Testing, Radiography Testing, Radiographic Film Interpretation, Magnetic Particle Testing, Liquid Penetrant Testing, Visual Testing, Leak Testing and Eddy Current Testing.

Condenser Tube Helium Leak Detection

Price 20000 INR/ Unit

MOQ : 1 Unit

  • Accuracy
  • 5%
  • Display
  • Digital LCD Display
  • Gas Pressure
  • 0.5 to 1.5 MPa
  • Humidity
  • 85% RH
  • Net Weight
  • approx. 60 kg
  • Number of Specimens
  • Up to 5 tubes simultaneously
  • Operating Mode
  • Manual and Automatic
  • Operating Temperature
  • 5C to 45C
  • Operating Voltage
  • 220 V AC, 50 Hz
  • Pedestal Size
  • Standard
  • Port Size
  • 6 mm
  • Power Supply
  • Single Phase 220 V 50 Hz
  • Response Time
  • 2 seconds
  • Sensor
  • High Sensitivity Helium Mass Spectrometer
  • Shell Material
  • Stainless Steel
  • Specimen Size
  • Tube Diameter: 6 mm to 40 mm
  • Temperature
  • 5C to 45C
  • Test Material
  • Metal (Condenser Tubes)
  • Test Medium
  • Helium Gas
  • Test Range
  • 1x10-9 to 1x10-5 mbar l/s
  • Type
  • Other, Leak Detection System
  • Use
  • Leak detection in condenser tubes and similar applications

Heat Exchanger Helium Leak Testing

Price 5000 INR/ Piece

MOQ : 1 , Piece

  • Accuracy
  • 2% of Reading
  • Display
  • Digital / Touchscreen
  • Gas Pressure
  • 1-10 Bar (Standard)
  • Humidity
  • 30% - 85% RH
  • Net Weight
  • 150-250 Kg (Varies by Model)
  • Number of Specimens
  • Single or Batch Testing (Customizable)
  • Operating Mode
  • Automatic & Manual
  • Operating Temperature
  • 10C to 50C
  • Operating Voltage
  • 220-240 V AC
  • Pedestal Size
  • Standard / Customizable
  • Port Size
  • 1/4 Inch / Customizable
  • Power Supply
  • Single Phase AC
  • Response Time
  • 2 seconds
  • Sensor
  • Helium Mass Spectrometer
  • Shell Material
  • Stainless Steel
  • Specimen Size
  • Up to 2 meters / Customizable
  • Temperature
  • 10C to 50C
  • Test Material
  • Heat Exchanger Tubes, Shells, Assemblies
  • Test Medium
  • Helium Gas
  • Test Range
  • 10^-6 mbar.l/s to 1 mbar.l/s
  • Type
  • Other, Helium Leak Detector
  • Use
  • Leak Testing of Heat Exchangers

Fugitive Emission Testing

Price 20000 INR/ Piece

MOQ : 1 Piece

  • Accuracy
  • 5%
  • Display
  • Digital
  • Gas Pressure
  • 0-24 bar
  • Humidity
  • 95% RH
  • Net Weight
  • 62 kg
  • Number of Specimens
  • 1
  • Operating Mode
  • Automatic
  • Operating Temperature
  • 10C to 40C
  • Operating Voltage
  • 230V AC
  • Pedestal Size
  • 82 x 42 x 65 mm
  • Port Size
  • DN 25/50/80/100 mm
  • Power Supply
  • 230V, 50Hz
  • Response Time
  • 1 second
  • Sensor
  • Helium Leak Detector
  • Shell Material
  • Stainless Steel
  • Specimen Size
  • DN 25-DN 100
  • Temperature
  • Ambient
  • Test Material
  • Valves
  • Test Medium
  • Helium or Methane
  • Test Range
  • 1x10 atm cc/sec to 1x10 atm cc/sec
  • Type
  • Other, Test Bench
  • Use
  • Leakage Testing, Valve Testing, Fugitive Emission Testing