ASNT Level II Helium Leak
ASNT Level II Helium Leak Specification
- Accuracy
- 0.1 %
- Operate Method
- Semi Automatic
- Color
- White
- Usage
- Industrial
- Material
- Mild Steel
- Type
- Electronic
ASNT Level II Helium Leak Trade Information
- Minimum Order Quantity
- 1 Number
- FOB Port
- At our Industrial Facility / Training Institute in Greater Noida
- Supply Ability
- 50 Per Week
- Delivery Time
- 4 Days
- Sample Available
- Yes
- Sample Policy
- Contact us for information regarding our sample policy
- Main Domestic Market
- North India
- Certifications
- NDT Level II in Helium Leak as per ASNT's written practice SNT-TC-1A
About ASNT Level II Helium Leak
Helium leak testing is a critical process in the engineering industry for ensuring the reliability and safety of vessels and valves that contain or transport pressurized gases or liquids. This testing method uses a small amount of helium gas as a tracer to detect leaks in the vessels and valves.
The process of helium leak testing involves several steps. First, the vessel or valve is evacuated to remove any gases or liquids that may be present. Then, helium gas is introduced into the vessel or valve, and the surrounding area is scanned with a helium detector. If a leak is present, the helium gas will escape from the vessel or valve and be detected by the detector.
Helium leak testing is a highly sensitive method that can detect leaks as small as 10 7 sacs (standard cubic centimeters per second).This level of sensitivity is critical in applications where even the smallest leaks can have serious consequences, such as in the transportation of toxic or explosive gases.
There are several benefits to using helium leak testing for vessels and valves. First, it is a non destructive testing method, meaning that the vessels and valves can be reused after testing. Second, it is a fast and accurate testing method, allowing engineers to quickly identify and address any leaks. Finally, it is a cost effective testing method, as it requires only a small amount of helium gas and minimal equipment.
In conclusion, helium leak testing is a critical process for ensuring the reliability and safety of vessels and valves in the engineering industry. Its sensitivity, accuracy, and cost effectiveness make it an essential testing method for applications where even the smallest leaks can have serious consequences.
Comprehensive Helium Leak Detection Training
Our ASNT-certified Level II training strengthens your understanding of helium leak detection techniques, including mass spectrometry and bubble testing, as per SNT-TC-1A standards. Youll use industry-leading equipment and receive both theoretical and practical instruction to build real-world competency. Training is delivered in English, with flexible scheduling and locations available across India.
Valid, Recognized Certification
Earn a globally acknowledged ASNT certification, respected throughout the NDT sector. The credential supports your professional development, verifying your ability to conduct helium leak testing and secure accurate results. Certification is valid for three years, ensuring enduring value for your career.
Hands-On Learning and Rigorous Assessment
Benefit from interactive instruction featuring actual helium leak detectors and bubble testing apparatus. Both written and practical evaluations are included, helping you master theoretical concepts and apply NDT reporting standards directly within workplace scenarios.
FAQs of ASNT Level II Helium Leak:
Q: How is the assessment conducted for ASNT Level II Helium Leak Detection certification?
A: Assessment takes place through both written examinations and hands-on practical evaluations conducted in English. You must demonstrate theoretical knowledge and practical competence using helium leak detectors and bubble testing apparatus.Q: What equipment will I use during the training and examination?
A: The training utilizes both a Helium Leak Detector and Bubble Testing Apparatus. These tools form the basis for practical exercises, allowing candidates to experience real-world leak detection techniques.Q: When and where are the classes held for this certification program?
A: Classes are scheduled as per the program calendar, with options for classroom or onsite instruction in various locations across India. The duration is variable depending on the schedule and participant requirements.Q: What is the process for obtaining the ASNT Level II Helium Leak Detection certificate?
A: First, enroll in the training and study the provided materials. Attend theoretical and practical sessions; complete both written and hands-on assessments following the ASNT SNT-TC-1A standard. On successful completion, you receive a certificate valid for three years.Q: How does this certification benefit my career in Non-Destructive Testing?
A: This ASNT certification demonstrates advanced proficiency in helium leak detection, enhancing your credibility and expanding employment opportunities within NDT, petrochemical, pharmaceutical, and power generation industries.Q: What study materials are provided to help with exam preparation?
A: Comprehensive study materials are included, covering both helium mass spectrometry and bubble leak testing techniques, standard reporting formats, and essential theory relevant to the certification.Q: Can I apply the skills learned to other leak detection methods?
A: While this training focuses on helium leak detection using specific techniques, the foundational NDT concepts and practical experience gained can strengthen your overall leak detection expertise and adaptability across similar test methods.
Price 16000 INR/ Number
- Minimum Order Quantity
- 1 Number
- Supply Ability
- 50 Per Week
- Delivery Time
- 4 Days
- Main Domestic Market
- North India
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Helium Leak Testings Category
Fugitive Emission Testing
Price 20000 INR / Piece
Minimum Order Quantity : 1 Piece
Pedestal Size : 82 x 42 x 65 mm
Test Medium : Helium or Methane
Humidity : 95% RH
Operating Temperature : 10C to 40C
Condenser Tube Helium Leak Detection
Price 20000 INR / Unit
Minimum Order Quantity : 1 Unit
Pedestal Size : Standard
Test Medium : Helium Gas
Humidity : 85% RH
Operating Temperature : 5C to 45C
Heat Exchanger Helium Leak Testing
Price 5000 INR / Piece
Minimum Order Quantity : 1 , Piece
Pedestal Size : Standard / Customizable
Test Medium : Helium Gas
Humidity : 30% 85% RH
Operating Temperature : 10C to 50C
Helium Leak Detection Service
Pedestal Size : Adjustable as per specimen
Test Medium : Helium Gas
Humidity : Up to 80% RH (noncondensing)
Operating Temperature : 5C to 45C
![]() |
INSPECTION & TESTING ENGINEERS
All Rights Reserved.(Terms of Use) Developed and Managed by Infocom Network Private Limited. |
English
Spanish
French
German
Italian
Chinese (Simplified)
Japanese
Korean
Arabic
Portuguese












